{"title":"Fire Alarm Call Points","description":"\u003cp\u003eManual call points and pull stations, indoor and outdoor, conventional and addressable.\u003c\/p\u003e","products":[{"product_id":"honeywell-notifier-nbg-12lx-fire-alarm-addressable-dual-action-pull-station-with-key-lock","title":"Notifier NBG-12LX Addressable Dual-Action Pull Station with Key Lock","description":"\u003cp\u003eThe Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eFeatures\u003c\/b\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\" class=\"uList\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMaintenance personnel can open station for inspection and address setting without causing an alarm condition.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBuilt-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHandle latches in down position and the word “ACTIVATED” appears to clearly indicate the station has been operated.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCaptive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG\/3.25 mm² wire).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCan be surface mounted (with SB-10 or SB-I\/O) or semiflush mounted. Semi-flush mount to a standard singlegang, double-gang, or 4\" (10.16 cm) square electrical box.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSmooth dual-action design.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets ADAAG controls and operating mechanisms guidelines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHighly visible.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAttractive shape and textured finish.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eKey reset.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIncludes Braille text on station handle.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOptional trim ring (BG12TR).\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeets UL 38, Standard for Manually Actuated Signaling Boxes.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUp to 99 NBG-12LX stations per loop on CLIP protocol loops.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUp to 159 NBG-12LX stations per loop on FlashScan® protocol loops.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDual-color LED blinks green to indicate normal on FlashScan® systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eConstruction\u003c\/b\u003e\u003cbr data-mce-fragment=\"1\"\u003e Shell, door, and handle are molded of durable polycarbonate material with a textured finish.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eInstallation\u003c\/b\u003e\u003cbr data-mce-fragment=\"1\"\u003e The NBG-12LX will mount semi-flush into a single-gang, double-gang, or standard 4\" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I\/O surface backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4\" (10.16 cm) or double-gang boxes (not with single-gang boxes).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eOperation\u003c\/b\u003e\u003cbr data-mce-fragment=\"1\"\u003e Pushing in, then pulling down on the handle causes it to latch in the down\/activated position. Once latched, the word “ACTIVATED” (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; closing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 – 159 on FlashScan® systems, 1 – 99 on CLIP systems).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eArchitectural\/Engineering Specifications\u003c\/b\u003e\u003cbr data-mce-fragment=\"1\"\u003e Manual Fire Alarm Stations shall be non-coded, with a keyoperated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I\/O; or semi-flush mounting on a standard single-gang, double-gang, or 4\" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national\/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eProduct Line Information\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eNBG-12LX:\u003c\/b\u003e Dual-action addressable pull station. Includes key locking feature.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSB-10:\u003c\/b\u003e Surface backbox; metal.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSB-I\/O:\u003c\/b\u003e Surface backbox; plastic.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eBG12TR:\u003c\/b\u003e Optional trim ring.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e17021:\u003c\/b\u003e Keys, set of two.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eNY-Plate:\u003c\/b\u003e New York City trim plate\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eNBG-12LX SPECIFICATIONS\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"productspecs\"\u003e\n\u003ctable style=\"width: 520.417px;\" cellspacing=\"2\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 112px;\"\u003eShipping Weight:\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 387.417px;\"\u003e9.6 oz. (272.15 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 112px;\"\u003eNormal Operating Voltage:\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 387.417px;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 112px;\"\u003eMaximum SLC loop voltage:\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 387.417px;\"\u003e28.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 112px;\"\u003eMaximul SLC loop current:\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 387.417px;\"\u003e375 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 112px;\"\u003eTemperature Range:\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 387.417px;\"\u003e32°F to 120°F (0°C to 49°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 112px;\"\u003eRelative Humidity:\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 387.417px;\"\u003e10%-93% noncondensing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 112px;\"\u003eUse:\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 387.417px;\"\u003eIndoors in a dry location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 112px;\"\u003eAgency Approvals:\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 387.417px;\"\u003e\n\u003cp\u003eIn some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status\u003c\/p\u003e\n\u003cp\u003eUL \/ CUL Listed: S692 (listed for Canadian and non-Canadian applications)\u003c\/p\u003e\n\u003cp\u003eMEA: 67-02-E\u003c\/p\u003e\n\u003cp\u003eCSFM: 7150-0028:0199\u003c\/p\u003e\n\u003cp\u003eFDNY: COA #6038 (NFS2-640), COA #6058 (NFS2-3030)\u003c\/p\u003e\n\u003cp\u003eBSMI: CI313066760047\u003c\/p\u003e\n\u003cp\u003eU.S. Coast Guard: 161.002\/23\/3 (AFP-200); 161.002\/27\/3 (AM-2020\/AFP-1010; 161.002\/42\/1 (NFS-640)\u003c\/p\u003e\n\u003cp\u003eLloyd’s Register: 02\/6007 (NFS-640); 94\/60004 (E2) (AFP-200); 03\/60011 (E1); 07\/60007 (NFS2-3030)\u003c\/p\u003e\n\u003cp\u003eFM Approved\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 112px;\"\u003ePatented:\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 387.417px;\"\u003ePatented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ctable style=\"width: 517.733px;\" cellspacing=\"2\" cellpadding=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"specName\" colspan=\"2\" style=\"width: 495.733px;\"\u003eExport Info\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"specName\" style=\"width: 148px;\"\u003eMade in\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 347.733px;\"\u003eMexico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":43499365236951,"sku":"ANTI FIRE-016","price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5361\/9415\/products\/NOTIFIER-NBG-12LX-IMAGE.jpg?v=1755231307"},{"product_id":"notifier-conventional-manual-outdoor-call-point-nbg-12lob","title":"Notifier NBG-12LOB Outdoor Conventional Manual Call Point","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDual-action pull station with key lock, outdoor applications listings (NBG-12LO), and backbox. Includes SB-I\/O indoor\/outdoor backbox, and sealing gasket. Model will also mount to WP-10 weatherproof backbox in retrofit applications.\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":43632335388887,"sku":"ANTI FIRE-073","price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5361\/9415\/products\/NOTIFIER-NBG-12LX-IMAGE_ce6d8887-802f-4dbd-9e65-7d9841fc4412.jpg?v=1755231318"},{"product_id":"notifier-nbg-12l-onventional-manual-call-point","title":"Notifier NBG-12L Conventional Manual Call Point","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDual-action pull station with SPST N\/O switch, screw terminal connections, Key lock\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":43632366911703,"sku":"ANTI FIRE-119","price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5361\/9415\/products\/NOTIFIER-NBG-12LX-IMAGE_bb783066-5f0f-4acf-a4b8-8656dc1d28c5.jpg?v=1755231322"},{"product_id":"notifier-nbg-12lr","title":"Notifier NBG-12LR Agent Release Pull Station","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDual-Action Agent Release Station\u003c\/p\u003e","brand":"Notifier","offers":[{"title":"Default Title","offer_id":43632376709335,"sku":"ANTI FIRE-086","price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5361\/9415\/products\/NBG-12LR_c35a69b8-4a76-4219-a16c-c6b21054e992.png?v=1755231323"},{"product_id":"farenhyt-manual-call-point-idp-pull-da","title":"Farenhyt IDP-PULL-DA Manual Call Point","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eDual-action addressable pull station requiring two motions to activate the station\u003c\/li\u003e\u003c\/ul\u003e","brand":"Farenhyt","offers":[{"title":"Default Title","offer_id":43632461971671,"sku":"ANTI FIRE-043","price":0.0,"currency_code":"EGP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5361\/9415\/products\/IDP-PULL-DA.png?v=1755231265"}],"url":"https:\/\/dalyexport.com\/collections\/fire-alarm-call-points.oembed","provider":"Daly Export","version":"1.0","type":"link"}